Toshiba air conditioners have become a trusted choice in Singapore due to their high efficiency, durability, and advanced inverter technology, which suits Singapore’s humid and warm environment. These are the top units of Toshiba air conditioners that many Singaporeans love:
- Toshiba RAS-24S3KS-V is the top-buy air conditioner among homeowners due to its superior energy efficiency and powerful DC Hybrid Inverter system.
- Toshiba RAS-N4KCVP is also one of the top-buy air conditioner inverters among Singaporeans due to its ultra-quiet operation and robust cooling performance.
- Toshiba RAS-13SKV-E3 is a top seller for small apartments and offices across Singapore.
Although Toshiba is known for its quality, that doesn’t mean that you won’t experience a few issues down the road. All air conditioners, even those made by reputable companies like Toshiba, will naturally run into a few problems.
But the good news is, your unit can display an error code to tell you what’s going on. Here’s a list of Toshiba aircon error codes, as well as their corresponding meanings.
Toshiba Aircon Error Code List
- C05: Central control sending error in TCC-Link central control devices
- C06: Central control receive error in TCC-Link central control device
- C12: Batch alarm for general purpose equipment interface
- E01: Communication between remote control and indoor unit
- E02: Local controller failure
- E03: Master indoor unit receives no data to A-B
- E04: Communication error between indoor and outdoor unit
- E06: Decrease of number of indoor units
- E07: Communication error between indoor and outdoor units
- E08: Duplicated indoor unit address
- E09: Multiple local controllers connected on a group – both configured as masters
- E1: Room temperature sensor error
- E2: Evaporator temperature sensor error
- E3: Condenser temperature sensor error
- E4: Display panel communication error
- E10: Indoor unit PSB failure
- E12: Automatic address start error
- E16: Maximum number of connected indoor units exceeded
- E18: Communication failure between master indoor unit and slave indoor unit or units
- E19: Number of header outdoor units error
- E20: Other line connected during automatic addressing
- E23: Sending error between outdoor units
- E25: Duplicated follower outdoor address setup
- F01: Indoor unit TCJ (Liquid) sensor error
- F02: Indoor unit TC2 (Vapour) sensor error
- F04: Outdoor unit TD (Discharge) sensor error
- F06: Outdoor unit TE (Coil) sensor open
- F07: Heat exchanger temperature sensor (TE) disconnect
- F08: Outdoor unit TO (Ambient) sensor open
- F10: Indoor unit TA (Return Air) sensor error
- F12: Suction temperature sensor (TS) disconnect
- F15: Outdoor temperature sensor (TE, TS) issue
- F29: Indoor unit PCB failure
- F31: Outdoor EEPROM error
- H01: Outdoor unit inverter compressor overcurrent
- H02: Master outdoor unit overcurrent
- H03: Current detected on master outdoor unit while idle
- H04: Abnormal overheat of compressor
- H06: Outdoor unit low pressure detected
- L03: Duplicated master indoor units in a group
- L07: Indoor unit in a group of units previously addressed as a single unit
- L08: Indoor unit addresses not set
- L09: Indoor unit capacity not set
- L10: Unset model type of service P.C. board
- L29: Outdoor unit IPDU error
- L30: Input on indoor PCB CN80 circuit for 1 minutes
- L31: Outdoor unit PCB error
- P01: Indoor unit fan motor error
- P03: Outdoor unit high discharge temperature
- P04: Outdoor unit high pressure switch activated
- P05: Power supply voltage error
- P07: Outdoor unit PCB heat sink overheated
- P1: Bottom tray is full
- P10: indoor unit float switch activated
- P12: Indoor unit fan motor error
- P15: Gas leak detected
- P19: Wrong change in temperature recorded
- P20: High pressure protective operation
- P22: Outdoor unit fan motor IPDU error
- P26: Outdoor unit giant transistor short circuit
- P29: Outdoor unit compressor error detected by feedback circuit
- P30: Indoor unit group control follower unit error / duplicated central control addresses
- P31: Indoor unit PCB error
- 0C: Short-circuit or disconnection of room temperature sensor
- 0d: Heat exchanger sensor (TC) out of place, disconnected, short-circuited, or migrated
- 0F: Heat exchanger sensor (TCj) out of place, disconnected, short-circuited, or migrated
- 04: Return serial signal is not sent to indoor side from operation started
- 07: Return signal has been sent when operation started but is not sent from halfway
- 08: Four-way valve inverse error
- 1A: Outdoor fan drive system error
- 1b: Outdoor temperature sensor (TO) out of place or short circuited
- 1C: Compressor drive output error
- 1d: Compressor not rotating
- 1E: Discharge temperature overheating
- 1F: Compressor breakdown
- 11: Indoor fan circuit
- 12: Indoor P.C boards issue
- 14: Inverter overcurrent
- 16: Position-detect circuit error or short circuit between windings of compressor
- 17: Current-detect circuit error
- 18: Heat exchanger sensor (TE) or suction temperature sensor (TS) out of place, disconnected, or short circuited
- 19: Discharge temperature sensor disconnected or short circuited
If the codes above don't work and you still face issues with your air conditioner, it might mean that you need repair from a professional. It’s always a good idea to see if your Toshiba air conditioner is still covered for free repairs or parts replacement.
For any issues, you can visit the official Toshiba Customer Service Center: 151 Lorong Chuan, New Tech Park (Lobby E) #04-05 Singapore 556741.
If your warranty has expired or you prefer to have your air conditioner serviced by a professional team, consider hiring our team at Luce SG. We offer reliable repair and maintenance services, ensuring your Toshiba air conditioner operates at peak performance!